AZUD LUXON LKM
| عنوان فارسی سری | عنوان انگلیسی سری |
|---|---|
| Standard series for low salinity water | LUXON LKM |
| Special series for seawater and high salinity water | LUXON LKM SW |
| Special series for high pressure (16 Bar) | LUXON LKM PN16 |
Automatic vertical screen filtration equipment electric commanded. Filtration surface of up to 21300 cm² and a maximum flow (for 800 micron) of up to 1475 m³/h. The cleaning mechanism includes rotating brush.
Technical Specifications
| Filter Type | Automatic screen filter for high flow rates (self-cleaning system) |
|---|---|
| TDS range | TDS < 6000 mg/l |
| Working pressure | Max: 10 bar (145 psi) Min: 0.8 bar (11.6 psi) |
| Min. flushing pressure | 2 bar (29 psi) |
| PH | 5 – 9 |
| Water temperature | ≤ 60 ℃ (140 ℉) |
| Filtration degrees | SS super duplex perforated plate * 3500 – 2500 – 1500 – 800 (micron), SS super duplex wedge wire screen 800 – 500 – 300 – 200 (micron) |
| Connections type | Flange ANSI B16.5, Flange DIN 2576 |
Other Features
Command : Electric motor command
Axis position : Vertical
Connection configuration : Angle
Body : Carbon steel with internal and external epoxy-polyester coating. PN10
Cartridge : SS 316L perforated plate or SS 304 wedge wire screen
Flushing Device : Motor, gearbox and SS304 rotating shaft scanner with nylon brushes
Inlet/Outlet connections : Ø 10”-20” (250-500 mm) – Flange (DIN 2576 / ANSI B16.5)
Drainage valve & connection : 2-way membrane with mechanical closure drainage valve – connection: flange –
Ø2” (50 mm) or Ø3” (80 mm) of epoxy-polyester coated cast iron – Hydraulic activation
Exhaust valve : Diaphragm 2-way valve
Manometer : ¼” BSP glycerine manometer male thread. bar/psi double scale (0-10 bar / 0-145 psi)
Control unit : AZUD FBC
Power supply : 380 V AC Three-phase
- Maximum flow for good quality water.
- It is possible for the manufacturer to change the technical specifications without prior notice.