AZUD HELIX AUTOMATIC FT200 AA DLP

عنوان فارسی سری عنوان انگلیسی سری
Standard series for low salinity waterFT200 AA DLP
Special series for seawater and high salinity waterFT200 AA SW DLP

Self-cleaning disc filtration equipment composed by 1 to 10 filters AZUD HELIX AUTOMATIC Ø2″ with discs AZUD MG/WS, which perform an in-depth 3D filtration, installed in-line on Ø2″-Ø8″ inlet/outlet manifolds. Includes Ø2″ backwash valves 3-way membrane type and the innovative DLP TECHNOLOGY, that enable the sequential low-pressure backwashing of each filter using a mix of filtered water and compressed air stored in an auxiliary tank, while continues the filtered water supply downstream. The patented AZUD HELIX anti-clogging deflector provides a reliable filtration thanks to an effect of centrifugal separation, with less backwash frequency and less water and energy consumption.

Smart, compact and modular plug&play solution, made of technical thermoplastics, increases the shelf life of the installation providing a long-term operation with minimum operational costs and less maintenance downtime.

Avda.

Technical Specifications

Filter Type

Helix automatic disk filter (self-cleaning system)

Num of filter

1-10 filters Ø2” (rPA)

TDS range

TDS < 6000 mg/l

Working pressure

Max: 10 bar (145 psi) Min: 0.8 bar (11.6 psi)

Min. flushing pressure

Max: 6 bar (87 psi), Min: 4.5 bar (65 psi)

Min. backwash flow

10 L water per filter

Air flow x duration

18 l/s (285 gpm) x 10 s

PH

4 – 11

Water temperature

≤ 60 ℃ (140 ℉)

Filtration degrees

1000 – 500 – 300 – 200 – 125 – 100 – 80 – 50 (micron)

Connections type

Flange ANSI B16.5 – Flange DIN 2576 – Grooved

Other Features

Pneumatic command (PN)
Air assisted backwash equipment
2 x 2” Diaphragm 3-way backwash valve for each filter – Pneumatic command (H)
Base-lid: rPA – Shaft: SS 303 – Seat: SS 304 – Spring: SS 302
Inlet/Outlet HDPE manifolds: Ø 2”-8” (50-200 mm) – Flange/Grooved
Drainage HDPE manifold: Ø3” (90 mm) – Grooved/PVC (Glue)
2 x ¼” BSP glycerine manometer male thread. bar/psi double scale (0-10 bar / 0-145 psi) per filtering elements, one on the auxiliary tank.
To view the filter specifications, refer to the technical specifications table of HELIX AUTOMATIC FT DLP series.

Model Num. of filter Filtration Area (cm2) Connections Inlet/Outlet Max. flow rate m3/h (gpm) - 130 micron Max. flow rate m3/h (gpm) - 50 micron Dimensions - L – W – H (mm)
FT201 AA1 filter Ø2”1620Ø2”21 (92)14 (62)605 – 475 – 1065
FT202 AA2 filter Ø2”3240Ø3”42 (185)28 (123)990 – 820 – 1310
FT203 AA3 filter Ø2”4860Ø3”
Ø4”
50 (220)
63 (277)
42 (185)1220 – 820 – 1330
FT204 AA4 filter Ø2”6480Ø4”
Ø6”
80 (352)
84 (370)
56 (247)1560 – 820 – 1380
FT205 AA5 filter Ø2”8100Ø4”
Ø6”
80 (352)
105 (462)
70 (308)1835 – 820 – 1380
FT206 AA6 filter Ø2”9720Ø6”126 (555)84 (370)2110 – 820 – 1380
FT207 AA7 filter Ø2”11340Ø6”147 (647)98 (432)2385 – 820 – 1380
FT208 AA8 filter Ø2”12960Ø6”
Ø8”
160 (705)
168 (740)
112 (493)2660 – 820 – 1420
FT209 AA9 filter Ø2”14580Ø6”
Ø8”
160 (705)
189 (832)
126 (555)2980 – 820 – 1420
FT210 AA10 filter Ø2”16200Ø6”
Ø8”
160 (705)
210 (925)
140 (616)3255 – 820 – 1420
  • 1 filter packages come with FBC 101 AA unit control.
  • 2-10 filter packages come with FBC 110 AA unit control.
  • It is possible for the manufacturer to change the technical specifications without prior notice.

Technical drawings